Failure of a road tanker pressure/vacuum relief valve
Health and Safety Executive - Safety alert
Department Name:
Chemicals, Explosives and Microbiological Hazards Division (CEMHD)
Bulletin No:
CEMHD2 – 2020
Issue Date:
01 March 2021
Target Audience:
All users, owners, operators and haulage contractors handling tank containers and road tanker barrels containing dangerous substances. Authorised inspection bodies inspecting and verifying valve performance on tank containers and road tanker barrels.
- Road Haulage Association
- British International Freight Association
- United Kingdom Warehousing Association
- Heavy Transport Association
- Logistics UK (previously known as Freight Transport Association)
- Food Storage and Distribution Federation
- Chemical Businesses Association
- SAFED
- British Valve and Actuator Association
Industries – Export and Import of dangerous chemicals (PIC), Offshore oil and gas, Ports and logistics
Topics – Carriage of dangerous goods, Pressure systems
Key Issues:
Bulk transport containers used for flammable, corrosive and toxic liquids and gases will normally have a pressure/vacuum relief valve fitted to prevent damage to the tank from changes in the internal pressure. These valves should be inspected and maintained in line with the manufacturer’s instructions.
Some valve designs require a special tool to dismantle them for servicing. Investigations by HSE found a technician had welded a nut on to the top of the valve to allow it to be dismantled without the use of a special tool.
The nut prevented the free movement of the valve stem, resulting in the valve sticking open and releasing hazardous vapours.
You should:
Visually inspect the pressure/vacuum relief valves fitted to tank containers (often referred to as iso-tanks) and road tankers used to transport dangerous substances. The inspection should establish if there have been any unauthorised modifications made to the valve, particularly items fixed to the valve to allow for easier dismantling.
Introduction
This safety alert is aimed at haulage contractors, users of tank containers and road tankers, companies servicing pressure/ vacuum relief valves and authorised inspection bodies contracted to verify the functioning of these valves.
Tank containers and road tankers used for flammable, corrosive and toxic liquids and gases will normally have a valve fitted to prevent damage to the tank from changes in the internal pressure. Haulage containers used for less hazardous liquids and gases may also have a valve.
Following a road incident in April 2020, investigations by Cleveland Police and HSE found evidence that a pressure/vacuum relief valve, originally manufactured by Fort Vale Engineering Ltd, had been modified by a third party. The valve cap had a nut welded to the top, most likely to allow it to be serviced without the use of a special tool to remove the valve cap. The unauthorised modification prevented the valve’s safe operation.

Figure 1 A new 2.5-inch combined pressure/vacuum relief valve

Figure 2 The same type of valve with an unauthorised modification and the locking grub screw missing
The welded nut prevented the free movement of the valve stem and resulted in the valve sticking in an open position. In this incident, the correct action by the vehicle driver minimised the release of hazardous vapour and prevented any harm to people or damage to property.
Background
In April 2020 the driver of an HGV hauling nitric acid noticed vapour coming from the tanker barrel in the area of the pressure/vacuum relief valve. He stopped at the roadside and rang the emergency services. Police closed the road and it remained closed until the tanker barrel had been fitted with a replacement valve. The tanker continued the short distance to its intended destination where it was safely discharged. There were no injuries or property damage although the road closure will have affected people and businesses nearby.
During what should have been a momentary operation to vent the road tanker, the vacuum relief element of the valve became stuck in an open position allowing an uncontrolled escape of hazardous vapour. The relief valve fitted to the tanker barrel had been modified in a way that made it unsafe. The flanged bolt on the end of the valve stem had been removed and a nut had been welded to the valve cap. The end of the valve stem was able to catch on the thread inside the nut, preventing the vacuum relief element of the valve from closing.
It is likely that this modification was made when the valve was removed for routine servicing. The addition of the nut allows the valve cap to be unscrewed without using a special tool. Some valves fitted to other road tankers operated by the same haulage contractor were found to have the same potentially dangerous modification.
The HSE investigation also noted:
- The removal of the vacuum valve stem top bolt could allow the valve to open so far that the stem fouls on the valve cap itself, this will also prevent the valve from closing
- The locking screw in the side of the valve body had not been replaced after the valve was reassembled after servicing. This locking screw prevents the valve cap rotating, which will change the pressure retaining capability of the valve
- The valve was being serviced less frequently than suggested by the manufacturer
- The valves vacuum protection function was not being routinely tested before refitting
The valve shown above is manufactured by Fort Vale Engineering Ltd (who are not implicated in any way). Unsafe modifications may also be applied to similar devices by other manufacturers.
Action required
Users of tank containers (iso-tanks) and road tankers used for carriage of dangerous liquids and gases
Users should visually inspect the pressure/vacuum relief valves fitted to tank containers and road tankers. The inspection should establish if there have been any unauthorised modifications made to the valve, particularly items added to the valve to allow for easier dismantling.
- People doing the inspection should refer to the original manufacturers design information to confirm the valve layout
- It is normally not necessary to remove or dismantle the valve to carry out a visual external inspection
- Safe access for working at height may be required if not already fitted to the tanker
Authorised inspection bodies
Inspectors witnessing pressure testing of tanker relief valves may need further information and training so they can visually identify unsafe modifications made to valves.
Where valves have both a pressure and vacuum relief function, then both the over-pressure and under-pressure safety functions should be verified during the pressure test.
Companies servicing pressure safety valves
Anyone working on relief valves should be competent to do so. Valves should be serviced following the valve manufacturer’s guidance. Valves should not have temporary nor permanent modifications in order to by-pass the need for special tools to carry out the work. Where a modification is felt necessary, the valve manufacturer or similar competent person should be consulted.
No need to inform HSE
There is no need to inform HSE of the outcome of any work carried out as a result of this safety alert.
Relevant legal documents
- Health and Safety at Work etc Act 1974
- Pressure Systems Safety Regulations 2000, Approved Code of Practice and guidance, L122. Second edition, 2014
- Provision and Use of Work Equipment Regulation 1998: Approved Code of Practice and guidance. L22. Fourth edition, 2014, amended 2018
References
- BS EN 14595 Tanks for transport of dangerous goods – service equipment - breather devices (available from British Standards Online)
- BS EN ISO 4126 Safety devices for the protection against excessive pressure (available from British Standards Online)
- ADR 2019, European Agreement Concerning the International Carriage of Dangerous Goods by Road. Volume 1, part 6.8 - Requirements for the construction, Equipment, type approval, inspection and tests of demountable tanks and tank containers, etc (The United Nations Economic Commission for Europe)
General note
Please pass this information to a colleague who may have this product/equipment or operate this type of system/process.