Air suspension systems on vehicles

Health and Safety Executive - Safety alert

Department Name:
Engagement and Policy Division

Bulletin No:
EPD 1 – 2020

Issue Date:
12.05.2020

Target Audience:
Those carrying out or responsible for work on vehicles with air suspension systems. This includes motor vehicle repair workshops, the roadside repair and recovery industry and customer sites where this work is undertaken.

Key Issues:
HSE have investigated several serious incidents involving air suspension systems on vehicles. The two main causes are collapse of inadequately supported vehicles and unintended rupture or release of components from the air suspension system.

You should

  • Undertake minimal repair work at the roadside or third-party premises. The best place to undertake such work is at an adequately equipped vehicle repair facility.
  • Prevent movement of air suspension, either by deflating the system or by using suitably rated props or stands to prevent the chassis lowering. Under no circumstances should air suspension be relied upon to maintain a vehicle's ride height or position whilst people gain access to areas where they may become trapped.
  • Exhaust the air from the air suspension system before working on it.
  • Isolate the air suspension system by physical disconnection of the air supply before working on it. You should not use clamping of air suspension pipework as a means of temporary isolation as it is not secure.

Introduction

Vehicles are commonly fitted with air suspension, including buses and coaches, refuse vehicles, goods vehicles and tankers.  On a vehicle with an air suspension system, inflated rubber bellows (also known as airbags) are supplied with air from the vehicle's air compressor via a storage system. These take the place of conventional springs at each wheel or axle and automatically ensure a consistent ride height, regardless of the load being carried. A typical set up is shown in Figure 1.

Air suspension systems on vehicles

Whilst these are produced by numerous manufacturers the hazards are common including;

Background

HSE have investigated several serious incidents, including fatalities, involving air suspension systems on vehicles that have failed. Causes of the incidents have included;

Action required

Those carrying out or responsible for work on vehicles fitted with air suspension systems should:

Ensure tasks are adequately planned. This includes; confirming the configuration of the particular suspension system, assessing the risks associated with each task, explaining each task so it is fully understood by the technician, providing the necessary equipment to undertake the job safely and developing safe systems of work. These should take into account the specific tasks and control measures required. You should support your staff if they are being put under pressure by third parties to work in an unsafe manner.

Undertake minimal repair work at the roadside or third-party premises. The best place to undertake such work is at an adequately equipped vehicle repair facility.

When working on vehicles with air suspension systems

  1. Prevent movement of suspension, either by fully deflating the system or by using suitably rated props or stands to prevent the chassis lowering. Under no circumstances should air suspension be relied upon to maintain a vehicle's ride height or position whilst people gain access to areas where they may become trapped. 
  2. If you are working near a lifting axle it should be isolated as it can move without notice.
  3. Carry out a visual check of the configuration and condition of the air suspension system.

When working on the air suspension system itself

  1. Undertake the actions above for working on vehicles with air suspension systems.
  2. Exhaust the air from the air suspension system before working on it.
  3. Isolate the system by physical disconnection of the air supply. The practice of temporary isolation by clamping of air suspension pipework (such as by mole grips) does not provide a secure isolation. In addition determine whether dissipation of stored air in the suspension system is required.
  4. For leak testing, visually inspect the empty system, then inflate and raise to full travel, leave a short period of time before inspecting for leaks. Should damage be identified, exhaust the air from the system before carrying out repairs. 

Relevant Legal Documents

Health and Safety at Work etc Act 1974, Sections 2 (1) and 3 (1).

References

General note

Please pass this information to others who carry out or are responsible for work undertaken on vehicles with air suspension systems and those operating premises where this work is undertaken.