Gas safety research
Current research projects
There are two research projects currently in progress, both being carried out by Advantica:
- CO Incident data for the year 2005/06, as part of the Joint Industry Programme (JIP).
- Ventilation in Floor/Ceiling
This is an industry-sponsored project looking at the advantageous ventilation provided in voids by modern construction methods. It is linked with compliance to regulation 19(6) of the Gas Safety (Installation and Use) Regulations 1998.
Completed research projects
- Reviews of CO information
- Combustion performance research
- CO detection inc. flueless gas fires and CO alarms
- Open flued appliances
- Other
Reviews of CO information
- A review of CO incident information for the five year period 1996/97 to 2000/01, produced from the full investigastion of domestic incidents which had resulted from the use of piped natural gas within Great Britain
- RR 439- A review of carbon monoxide incident information for 2003/04: Produced from the full investigation of incidents which had resulted from the use of piped natural gas and LPG within Great Britain
- RR 238- A review of carbon monoxide incident information for 2002/03
- RR163- A review of carbon monoxide incident information for 2001/02: Produced from the full investigation of incidents which had resulted from the use of piped natural gas and LPG within Great Britain
- CRR 424/2002- A review of carbon monoxide incident information for 1999/2000
- CRR 376/2001- A review of carbon monoxide incident information for 1998/9 produced from the full investigation of incidents which had resulted from the use of piped natural gas and LPG within Great Britain
- CRR 375/2001- A review of carbon monoxide incident information for 1997/8 produced from the full investigation of incidents which had resulted from the use of piped natural gas and LPG within Great Britain
- CRR 374/2001- A review of carbon monoxide incident information for 1996/7 produced from the full investigation of incidents which had resulted from the use of piped natural gas and LPG within Great Britain
- CRR 386/2001- Reducing carbon monoxide incidents
Combustion performance research
Combustion performance safety action levels for domestic gas appliances
CO detection inc. flue gas analysers and CO alarms
- Initial evaluation of proposed procedures for the measurement of gas appliance CO emissions [263KB]
- Further evaluation of proposed procedures for the measurement of gas appliance CO emissions [194KB]
- A review of gas appliance CO emissions legislation [257KB]
- The development and testing of a methodology for using Flue Gas Analyser measurements to assess domestic gas appliance combustion [2MB]
- RR023- Flueless gas fires - concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide, and particulate level produced in use
- RR127- Measurement and modelling of combustion products from flueless gas appliances
- RR165- Continued appraisal of domestic CO alarms
- CRR 360/2001- Long-term reliability of domestic CO alarms
- CRR 378/2001- A market survey of portable carbon monoxide detection equipment
- CRR 382/2001- The siting of domestic CO alarms - an analysis of full scale vitiation tests
- CRR 406/2002- Assessment of methods to detect leaks in the casing of room sealed appliances
Open flued appliances
- CRR 379/2001- Experiments to study the effects of ventilator size and location on the operation of open flued gas boilers when operated within a compartment
- CRR 380/2001- Experimental work to study the interaction between air extraction equipment and open-flued- phase 1
- CRR 381/2001 - Experimental work to study the interaction between air extraction and open-flued - phase 2
- CRR 384/2001 - Vitiation studies of an open-flued central heater boiler operated in compartments
Other
- HSL 2005/11 - CFD modelling of low pressure jets for area classification [456KB]
- RR288- Development of a ventilator test procedure to take account of external wind conditions
- CRR 377/2001- A review of the emergency response related to CO fumes incidents
- CRR 383/2001- An analysis of full scale data to assess factors affecting vitiation associated with gas appliances
- CRR 385/2001- The impact of the HSC/E: A review
- CRR 416/2002- Flue performance of domestic gas burning appliances: the effect of ventilation strategies on flue performance
- CRR 449/2002- Air quality measurements in commercial kitchens